   about us       Model: MSDP-880/ 882    
   news    

 

 
   
  electronic meters/control devices

     
  Digit PowerMeter

     
  MSDP-800        
  MSDP-300        
  MSDP-880/ 882        
  Demand Control      
  MSDM-900        
  V and A Meter      
  MSDP-883        
  Kilowatt-Hour Meter      
  MSDP-700/702        
  PF Regulator

       
  MSPFR-806/ 812     Characteristic features:    
  APFR-6    

◇Clustered synthesized power meter simultaneous display of a multitude of data:

Three-Phase Voltage(V), Three-Phase Current(A), Actual Wattage(KW), Consumption (KVH), Reactive Power(KVAR), Frequency(HZ), Power Factor(PF), Reactive Energy (KVARH)。


◇Programmable replay:
All the data permissible for Upper/Lower Limit Alarm Setting, as well as four sets of programmable controlled outputs. Relay ON/OFF permissible for the setting of delay time, ranging from 0 to 999 seconds, may also display exact present-time readings.


◇CT、PT ratios adjustable at user's discretion:
CT、PT ratios adjustable directly on the panel in applications involving HV、LV panels and considerable power consumption.


◇Actual wattage(KW) may be set on four settings:
Ideal for management of contractual capacities, which helps to reduce energy consumption and is reflected in the savings of power supply costs.


◇Power factor leading display:
Serves to monitor Power Factor Leading Displays, helps to minimize Phase-led Capacitors and power consumption, thereby reducing power rate costs.


◇RS 232 or RS 422 communication interfacing:
May run on-line with computer to serve as Master Power Monitor system at a plant or to collect data.
Power Demand Management and Power Demand Control complete with meter indicating present Maximum Demand, and with permissibility for four steps Demand Control。

   
  Power Converter

     
  MSDP-200        
  signal Converter

     
  Signal Transducer        
  AC Welding Anti-Shock Device

     
  MSES-500        
  power control system

     
  Power Control System        
  Demand Control System        
  Power Factor Controller        
  plating machines/accessories      
   contact us 

 

     
           
           
           
           
           
           
           
           
           
           
           
           
                 
        Function & Range:    
       
UNIT
RANGE
ACCURACY
AC Voltage 0~ 999KV
± 0.2%
AC Current 0~ 6000A
± 0.2%
Wattmeter 0~ 9999MW
± 1.0%
Kilowatt Hour Meter 0~ 99999MWH

± 1.0%

Power Factor 0.00~ 1.00
± 2.0%
Frequency Meter 40.0~ 70.0HZ
± 0.1%
KVA 0~ 9999MVA
± 0.4%
KVAR 0~ 9999MVAR
± 0.4%
KVAR Hour Meter 0~ 9999MVARH
± 1.0%
Demand Meter 0~ 9999MW
± 1.0%
Max. Demand Meter 0~9999MW
± 1.0%
Ground Leakage 0~ 6000A
± 0.5%

 

   
                 
        Functions of each type:    
       
TYPE MSDP-880- MSDP-882-
Display Items 1 2 3 4 5   1 2 3 4 5 6
3 Phase Voltage  
3 Phase Current  
Power Factor  
Watt/Active Power  
Kilowatt Hour Meter  
Frequency Meter  
KVA/ Apparent Power            
KVAR/ Reactive Power            
KVAR Hour Meter            
RS-232C Interface  
Analog Output  
Programmable Setter  
Switching Time Delay  
KWH Pulse Output                    
Lead/ Lag Display                    
Ground Leakage                    
Demand Meter                  
Maximum Demand                  
Demand Controller                      
   
        (Explanation of Demand)        
                 
                 
                 
       
  Minsun Technology Co., Ltd
  15, Lane 210, Jeanshin St. Shulin City, Taipei Hsien, Taiwan R.O.C
 
  Tel : 886-2-2689-4051~2 
  Fax: 886-2-2688-0109
  91,GUNGMINGNAN 1 RD., TAINAN, TAIWAN, R.O.C.
  Tel : 886-6-246-4745~6   
  Fax: 886-6-246-4750
  E-mail:minsunt@gmail.com
  http://www.minsun.com
   
       